T-5000
INTEGRATED TELECOM FUEL CELL SOLUTIONS
-Cost savings over diesel power, even while reducing carbon output
-Remotely accessible for real-time control & monitoring
-Anti-theft solution ( fuel source does not have a resale value )
-Optional extended-run / auxiliary fuel tank cabinets
-Quiet Operation, clean Power
-Lower energy cost, Lower Maintenance
-No carbon monoxide NOx or SOx emissions
-Can be hybrized with solar or wind power
APPLICATIONS
-Telecom UPS
-Remote Monitoring
-Rail & Signals
-Marine
-Government
-Security & Surveillance
-Remote Area Power
- Power Rating: 0 a 5KW @ 20°C a 101.3 kPa
- Current Rating: 0 a 47A *2 @54V
OPERATION
- Voltage adjustable: 43.2 a 57.6 Vdc
- Voltage ripple: +- 1V
- Altitude De-rating: 3.5% per 500m over 1,000m
- Temperature De-rating: 1.25% per °C over 40°C
- Stand-by Power Consumption: Approximately <3% at peak power (DC)
- Reactantsi: Hydrogen and Air
- Cooling: Air ( integrated cooling fan )
- H2 inlet pressure: 0.55-0.75 bar
- Hydrogen purity: ? 99.995% dry H2
- Consumption: ? 0.78 Nm3/kWh (Average at max load)
- Start up time: ? 2 minute at ambient temperature
- Efficiency of stack: ? 42% at peak power
- Max Noise: Normal operation: < 70 dBa at 1.5 meters
FOOTPRINT
- Controller Dimension (WxDxH): (430mm x 550mm x 150mm) *2
- Stack Dimension (WxDxH): (430mm x 550mm x 356mm) *2
- Controller weight: 15 *2 kgs
- Stack weight ( with accessory and case ): 40.3 *2 kgs
ENVIRONMENT CONDITION
- Ambient temperature: -10°C a +45°C standard ( winter kit needed when temperature is below 0°C, during operation )
- Recommended cold start temp: above 5°C
- Relative Humidity: 0 - 95% No - Condensing
- Storage Temperature: -20°C a +50°C Standard
COMMUNICATION
- RS485 o RS232