Solenoid Valve ATEX H2
Essential Health and Safety Requirements:
Solenoid operators types WBLP are designed in
accordance with IEC and EN Standards
references: 60079-0, 60079-7, 60079-18 and
60079-31.
Classification:
• II 2 G Ex e mb IIC T4 Gb
• II 2 D Ex tb IIIC T135°C Db IP67
Function = 2/2 normally closed – direct acting
Fluid temperature -10°C /+ 100°C
Operating Pressure = min 0 bar
Operating Pressure = max 30 bar
Maximum allowable pressure = 50 bar
Orifice size = 1,2 mm
Port size = G1/8 – ISO 228
Materials in contact with fluid
Body = brass
Sealing = fpm
Internal components = stainless steel
Seat = brass
Core tube = stainless steel
Shading coil = copper
COIL SPECIFICATIONS
Electrical connection = Cable gland (EN 60079-0)
Voltage = 12 VDC
Power absorption = 4 W
Coil insulation material = PBT - 40
Coil insulation = class F
Ambient temperature = -10°C /+ 65°C
Protection degree = IP67
Mounting position = Any – vertical with coil upwards preferred