H2Maker EL Software
H2Maker EL is the supervision and monitoring software designed for PEM electrolysers. Connected to the electrolyzer via an Ethernet network, it allows you to monitor the system’s operation in real time and keep the main process parameters under constant control.
From the dashboard, you can start, stop, and reset the machine, as well as set the Hâ‚‚ flow setpoint. Hydrogen pressure and flow, cell current and voltage, water temperature, and other process parameters are displayed directly on the interface.
The software also allows you to track parameter trends through real-time graphs, view the machine’s status and active alarms, and automatically log measurements. Data is stored in daily CSV files, which are easy to view and process in Excel, with the option to export the current display as well.
A single environment to control, monitor, and document the operation of your electrolyzer.
KeyFeatures:
- Real-time control — start, stop, reset, and adjustment of the Hâ‚‚ production setpoint.
- Parameter monitoring — Hâ‚‚ pressure and flow, cell current and voltage, water temperature and conductivity.
- Status and alarms — machine operating status and active faults are always visible.
- Live Trends Graphs — display of trends for Hâ‚‚ flow, Hâ‚‚ pressure, cell current/voltage, and water temperature.
- Automatic data logging — recording of readings with daily archiving in CSV format.
- Data export — ability to export the current display for further analysis.
- Multilingual interface — Italian, English, Spanish, French, and German.
- Ethernet/Modbus TCP connection — connects to the electrolyzer via an IP address and configurable port; port 502 is shown on the screens.
- Configurable polling — user-configurable data acquisition interval; in the configuration shown, it is set to 1.00 s.
- Compatibility — Windows and macOS.
- Software Type: Supervision and monitoring software for PEM electrolysers
- Communication: Ethernet / Modbus TCP
- Network Configuration: Configurable IP address
- Communication Port: 502 (configurable)
- Polling rate: Configurable; setting shown: 1.00 s
- Machine controls: START / STOP / RESET
- Hâ‚‚ setpoint: Adjustment via software interface
- Hâ‚‚ flow unit: ml/min
- Hâ‚‚ pressure: bar
- Cell current: A
- Cell voltage: V
- Water temperature: °C
- Water conductivity: µS
- Monitored temperatures: Hâ‚‚O, Tower A, Tower B
- Data display: Dashboard + real-time graphs
- Available trends: Hâ‚‚ flow, Hâ‚‚ pressure, cell current/voltage, Hâ‚‚O temperature
- Machine status: Operational status display
- Alarm management: Display of active alarms
- Data logging: Automatic
- Data format: CSV
- Archiving: Daily files
- Export: Export current view
- Data viewable in history: Time, Hâ‚‚ pressure, Hâ‚‚ flow, % production, current, voltage, Hâ‚‚O temperature, Tower A, Tower B, status/alarms
- Languages: Italian, English, Spanish, French, German